CONSIDERATIONS ON THE DIFFUSE SEISMICITY ASSUMPTION
2015; Volume: 12; Issue: 2 Linguagem: Inglês
10.5335/rsee.v12i2.4544
ISSN2316-2457
AutoresJorge Daniel Riera, Ignácio Iturrioz,
Tópico(s)Structural Engineering and Vibration Analysis
ResumoSecond-order effects were historically included by the effective length method (K concept). All the studies about that methodology have been developed in frame plane, with regular rectangular frames. The new way to include those effects is the use of second-order analysis, direct analysis method or alternative simplified options. This methodology was included in ANSI AISC360 in the 2005 version and in the 2010 version. As before, the studies already developed for DAM analysis are in plane. In this paper, the K concept is revisited by numerical analysis, and extended to the 3D space. Using models of symmetric and non-symmetric industrial steel structures in plane, 3D stability analyses were developed, and the results were compared with plane behavior. Several conclusions and recommendations were exposed, resulting from the analyzed models. Keywords: Second-order analyses, steel structures, irregular 3D frames.
Referência(s)