Artigo Revisado por pares

The intergranular corrosion susceptibility of 2024 Al alloy during re–ageing after solution treating and cold–rolling

2016; Elsevier BV; Volume: 114; Linguagem: Inglês

10.1016/j.corsci.2016.11.013

ISSN

1879-0496

Autores

Zhixiu Wang, Peng Chen, Hai Li, Bijun Fang, Renguo Song, Ziqiao Zheng,

Tópico(s)

Corrosion Behavior and Inhibition

Resumo

The intergranular corrosion (IGC) susceptibility of 2024 Al alloy during re–ageing after solution treating and cold–rolling was investigated by accelerated corrosion testing, open circuit potential testing, transmission electron microscopy and scanning electron microscopy. The absence of IGC in both the peak–re–aged and over–re–aged samples is related to the dislocation pile–ups which prevent the supersaturated solutes from diffusing into the grain boundaries and precipitating the continuous S–Al2CuMg phase. The aggregated pitting corrosion in the over–re–aged samples arises from the S–phase precipitates on the dislocation cell walls which accelerate the anodic dissolution of the cell interiors.

Referência(s)
Altmetric
PlumX