Artigo Acesso aberto Revisado por pares

Power Routing for Cascaded H-Bridge Converters

2017; Institute of Electrical and Electronics Engineers; Volume: 32; Issue: 12 Linguagem: Inglês

10.1109/tpel.2017.2658182

ISSN

1941-0107

Autores

Youngjong Ko, Markus Andresen, Giampaolo Buticchi, Marco Liserre,

Tópico(s)

HVDC Systems and Fault Protection

Resumo

Modular power converters are expected to play a major role in medium- and high-voltage/power applications. Normally, each module processes the same amount of power; however, this does not take into consideration that different modules can have a different remaining useful lifetime. This paper proposes the concept of power routing for cascaded H-bridge (CHB) converters, with the purpose of delaying the failure of the system. A third-harmonic injection into the duty cycles allows extending the imbalance capability of the structure, keeping the CHB operational even if some power paths are completely unloaded. Analytic investigation in conjunction with simulation and experimental measurements demonstrate the power routing by means of the proposed method.

Referência(s)