Artigo Acesso aberto Revisado por pares

Bulk-Fill restorative materials in primary tooth: An intrapulpal temperature changes study

2018; Medknow; Volume: 9; Issue: 5 Linguagem: Inglês

10.4103/ccd.ccd_23_18

ISSN

0976-237X

Autores

Halenur Altan, Zeynep Göztaş, Zeki Arslanoğlu,

Tópico(s)

Dental Research and COVID-19

Resumo

It was aimed to investigate the temperature changes in primary teeth pulp chamber during the curing/setting of bulk-fill restorative materials with different nanoparticle contents.Twenty-five extracted, primary mandibular second molars were prepared as a Class II cavity. Five bulk-fill restorative materials consisting of Equia Fil (HVGIC), glass carbomer (GC) cement, Sonic Fill (SF), X-tra Fil (XF), and Quix Fil (QF) were tested. The measurement of the pulp chamber temperature changes (starting temperature 37°C) during setting/curing was performed with a J type thermocouple. The data, differences between highest and initial temperature values, were recorded and analyzed by one-way ANOVA.The temperature changes in the pulp chamber were in EF (2.81°C), GC (7.92°C), SF (3.33°C), XF (3.43°C), and QF (3.02°C). There were statistically significant differences between temperature changes in groups (P < 0.05).The tested bulk-fill resin composites and high-viscosity glass ionomer cement do not increase the intrapulpal temperature in primary teeth during the curing/setting.

Referência(s)