First experience of transcatheter implantation of a Russian-made MedLab-CT prosthesis in a patient with dysfunction of biological mitral valve prosthesis
2020; Russian Society of Cardiology; Volume: 25; Issue: 8 Linguagem: Inglês
10.15829/1560-4071-2020-3847
ISSN2618-7620
AutoresA. V. Bogachev-Prokofiev, Ravil Sharifulin, M. A. Ovcharov, Alexey Pivkin, Oleg Krestyaninov, T. V. Antropova, M. A. Ovchinnikova, Д. А. Астапов, Andrey Sapegin, Alexander Afanasyev, S.A. Budagaev, С. И. Железнев,
Tópico(s)Cardiac Structural Anomalies and Repair
ResumoWe present a case report of successful transcatheter implantation of a Russian-made cardiac valve prosthesis in a patient with dysfunction of biological mitral valve prosthesis (valve-in-valve). A patient aged 78 years with a high surgical risk and severe heart failure due to mitral valve bioprosthesis dysfunction is described. Fluoroscopyand transesophageal echocardiography-guided transapical implantation of a MedLab-CT prosthesis (23 mm) was made. When a heart rate of 180 beats per minute, a stent prosthesis was implanted. Transcatheter implant valve functioned properly after surgery. The patient was discharged in satisfactory condition.
Referência(s)