Artigo Acesso aberto Revisado por pares

A comparative study of Williamson-Hall method and size-strain method through X-ray diffraction pattern of cadmium oxide nanoparticle

2020; American Institute of Physics; Linguagem: Inglês

10.1063/5.0033762

ISSN

1935-0465

Autores

Suhir Abd-Alaziz Jabir, Khalid Hellal Harbbi,

Tópico(s)

Polymer Nanocomposite Synthesis and Irradiation

Resumo

In this research, the Williamson-Hall method and of size-strain plot method was employed to analyze X- ray lines for evaluating the crystallite size and lattice strain and of cadmium oxide nanoparticles. the crystallite size value is (15.2 nm) and (93.1 nm) and lattice strain (4.2 x10−4 ) and (21x10−4) respectively. Also, other methods have been employed to evaluate the crystallite size. The current methods are (Sherrer and modified Sherrer methods ) and their results are (14.8 nm) and (13.9nm) respectively. Each method of analysis has a different result because the alteration in the crystallite size and lattice strain calculated according to the Williamson-Hall and size-strain plot methods shows that the non-uniform strain in nanoparticles.

Referência(s)
Altmetric
PlumX