Artigo Acesso aberto

Clinical screening tools for obstructive sleep apnea in a population with atrial fibrillation: a diagnostic accuracy trial

2021; American Academy of Sleep Medicine; Volume: 17; Issue: 5 Linguagem: Inglês

10.5664/jcsm.9098

ISSN

1550-9397

Autores

Anna M. Mohammadieh, Kate Sutherland, Logan Kanagaratnam, David Whalley, Mark Gillett, Peter A. Cistulli,

Tópico(s)

Tracheal and airway disorders

Resumo

Free AccessScientific InvestigationsClinical screening tools for obstructive sleep apnea in a population with atrial fibrillation: a diagnostic accuracy trial Anna M. Mohammadieh, BA, MBBS, Kate Sutherland, BSc (Hons), PhD, Logan B. Kanagaratnam, MBBS, David W. Whalley, MBBS (Hons), PhD, Mark J. Gillett, MBBS, MClincEd, Peter A. Cistulli, MBBS, PhD, MBA Anna M. Mohammadieh, BA, MBBS Address correspondence to: Anna M. Mohammadieh, BA, MBBS, Department of Respiratory and Sleep Medicine, Level 8, Acute Services Building, Royal North Shore Hospital, St Leonards NSW 2066, Australia; Tel: +612 9926 7111; Fax: +612 9463 2097; Email: E-mail Address: [email protected] Department of Respiratory and Sleep Medicine, Royal North Shore Hospital, Sydney, Australia Charles Perkins Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia Search for more papers by this author , Kate Sutherland, BSc (Hons), PhD Department of Respiratory and Sleep Medicine, Royal North Shore Hospital, Sydney, Australia Charles Perkins Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia Search for more papers by this author , Logan B. Kanagaratnam, MBBS Department of Cardiology, Royal North Shore Hospital, Sydney, Australia Faculty of Medicine and Health, The University of Sydney, Sydney, Australia Search for more papers by this author , David W. Whalley, MBBS (Hons), PhD Department of Cardiology, Royal North Shore Hospital, Sydney, Australia Faculty of Medicine and Health, The University of Sydney, Sydney, Australia Search for more papers by this author , Mark J. Gillett, MBBS, MClincEd Faculty of Medicine and Health, The University of Sydney, Sydney, Australia Department of Emergency Medicine, Royal North Shore Hospital, Sydney, Australia Search for more papers by this author , Peter A. Cistulli, MBBS, PhD, MBA Department of Respiratory and Sleep Medicine, Royal North Shore Hospital, Sydney, Australia Charles Perkins Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia Search for more papers by this author Published Online:May 1, 2021https://doi.org/10.5664/jcsm.9098Cited by:8SectionsAbstractEpubPDFSupplemental Material ShareShare onFacebookTwitterLinkedInRedditEmail ToolsAdd to favoritesDownload CitationsTrack Citations AboutABSTRACTStudy Objectives:Although obstructive sleep apnea (OSA) is a known risk factor for atrial fibrillation (AF), there is a paucity of data around its diagnosis and management in patients with AF. The objectives of this study were to compare the diagnostic accuracy of commonly used OSA screening tools in an AF population, including a level 3 portable sleep study device, and to examine the epidemiology of OSA in a hospital cohort with AF.Methods:One hundred seven patients with AF recruited from 2 tertiary centers underwent a panel of OSA screening tools and in-laboratory polysomnography in randomized order.Results:Oxygen desaturation index derived from a level 3 portable sleep study device performed best for moderate to severe and severe OSA, with excellent diagnostic accuracy (area under the curve, 0.899; 95% confidence interval, 0.838–0.960 and area under the curve, 0.925; 95% confidence interval, 0.859–0.991, respectively). Sixty-seven patients (62.6%) were newly diagnosed with OSA (31.8% mild, 18.7% moderate, 12.1% severe).Conclusions:Undiagnosed OSA is highly prevalent in a hospital AF cohort. However, it is characterized by a relative paucity of symptoms, markedly limiting the usefulness of history or screening questionnaires. This is the first study to find that a level 3 home sleep study device shows excellent diagnostic accuracy in patients with AF. This finding may inform AF management guidelines.Clinical Trial Registration:Registry: Australian New Zealand Clinical Trials Registry; Name: The validity and reliability of a portable device for the diagnosis of Obstructive Sleep Apnoea in patients with Atrial Fibrillation; URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=371024; Identifier: ACTRN12616001016426.Citation:Mohammadieh AM, Sutherland K, Kanagaratnam LB, Whalley DW, Gillett MJ, Cistulli PA. Clinical screening tools for obstructive sleep apnea in a population with atrial fibrillation: a diagnostic accuracy trial. J Clin Sleep Med. 2021;17(5):1015–1024.BRIEF SUMMARYCurrent Knowledge/Study Rationale: Obstructive sleep apnea (OSA) is a known risk factor for atrial fibrillation (AF). However, international AF guidelines lack clarity around the approach to the diagnosis and management of OSA.Study Impact: Our study shows that traditional OSA symptoms including snoring, self-reported sleepiness, and obesity are inadequate for the detection of moderate to severe OSA in an AF population. A level 3 portable sleep study device showed excellent diagnostic accuracy in a hospital-based AF population and may be useful as a screening tool in patients with AF.INTRODUCTIONThe association between obstructive sleep apnea (OSA) and atrial fibrillation (AF) is well described.1–3 Studies have consistently shown a higher prevalence of OSA among patients with AF patients as compared with control patients—for example, 62% vs 38%.4 Animal and human experimental studies have confirmed that OSA increases AF inducibility, both acutely, in response to individual apneic events, and via chronic atrial remodeling pathways.5–7 Several nonrandomized studies have reported that OSA increases the risk of AF recurrence after cardioversion and ablative procedures, a risk that appears to be mitigated by effective OSA treatment.8–12 OSA is an independent risk factor for ischemic stroke in patients with AF.13Although clinical guidelines acknowledge the role of OSA as a risk factor for AF, they lack clarity in the approach to its diagnosis and management.14–17 Guidelines from the American Heart Association/American College of Cardiology/Heart Rhythm Society suggest that weight loss is recommended for patients with AF who are obese along with modification of risk factors, including OSA.16 However, the diagnostic strategy to identify OSA is not elaborated in the guidelines, and the treatment of OSA in patients who are not obese is not discussed. Recently published guidelines from the European Heart Rhythm Association/European Society of Cardiology (EHRA/ESC) recommend that optimal management of OSA may be considered to reduce AF incidence, progression, recurrence, and symptoms. However, they also report a gap in current knowledge about how and when to test for OSA in patients with AF.17 These inconsistencies highlight a paucity of evidence around the screening and management of OSA in patients with AF.The gold standard investigation for the diagnosis of OSA, in-laboratory polysomnography (PSG), is a resource-intensive investigation requiring overnight admission in a specialist center and may be inaccessible to many patients. In practice, patients with AF may be referred for PSG at the discretion of their treating physician on the basis of clinical suspicion of OSA. However, it is unclear how to identify which patients with AF are most at risk of OSA. A recently published study highlighted the prevalence of undiagnosed OSA in patients awaiting AF ablation and concluded that more research is required to identify the optimal method to test for sleep apnea in patients with AF.18The primary aim of this study was to evaluate the validity of a number of commonly used OSA screening tools in patients with AF, including snoring, obesity, daytime hypersomnolence, and airway crowding using symptom-based questionnaires and a level 3 portable sleep study performed at home. A secondary aim was to examine the epidemiology of OSA in a hospital cohort with AF.METHODSApproval was obtained from the Northern Sydney (Australia) Local Health District Human Research Ethics Committee (HREC/16/HAWKE/25) at Royal North Shore Hospital (Sydney) and the North Shore Private Hospital (Sydney) Ethics Committee (approval number 2016-012). All patients gave their informed written consent to participate in the study. The trial was registered with the Australian New Zealand Clinical Trials Registry (Identifier: 12616001016426).To compare the presence and severity of OSA across clinical AF phenotypes, patients were recruited via 2 hospital-based clinical pathways: (1) emergency department (ED) presentations with confirmed AF and (2) pulmonary vein isolation (PVI) waitlist in the departments of cardiology at 2 specialist centers. All patients had an electrocardiogram-documented history of ≥ 1 episode of AF in the last 12 months. Patients waiting for PVI were sequentially recruited over the duration of the study period (July 2016–September 2019). Because of large numbers of ED presentations during the study period, patients in the ED were sequentially recruited within 3 discrete time intervals during the study period (July 2016–November 2016, September 2017–February 2018, and July 2018–December 2018). Exclusion criteria are outlined in the study flowchart (Figure 1).Figure 1: Study flowchart.*Reasons for study ineligibility (n = 231): 67 (29.0%) patients had significant geriatric health issues (eg, falls, frequent urinary tract infections, impaired mobility); 43 (18.6%) had no definite history of documented AF; 29 (12.6%) had active malignancy; 25 (10.8%) had repeat presentation; 24 (10.4%) were geographically remote and unable to travel to the study; 12 (5.2%) had end-stage organ disease; 8 (3.5%) had significant cognitive impairment; 7 (3.0%) had significant mental illness; 6 (2.6%) had active substance abuse; 1 (0.4%) was deceased; 1 (0.4%) was intubated; and 8 (3.5%) were otherwise unable to provide written informed consent. †Patient-reported reasons for declining study participation (n = 103): 30 (29.1%) patients had no reason given; 22 (21.4%) were too busy/had no time; 16 (15.6%) were not interested; 9 (8.7%) said a diagnostic sleep study was already performed; 7 (6.8%) were too unwell to participate/had too many medical appointments; 6 (5.8%) had no OSA symptoms; 4 (3.9%) were already diagnosed with OSA (not on treatment); and 10 (1.0%) disclosed “other reason.” AF = atrial fibrillation, CPAP = continuous positive airway pressure, OSA = obstructive sleep apnea, PSG = polysomnography, PVI = pulmonary vein isolation.Download FigureAll patients undertook a baseline interview for the collection of demographic and anthropometric data including age, sex, ethnicity, body mass index, and neck circumference. Comorbidities and AF risk factors were documented from patient interviews and corroborating medical record reviews, including the presence of diabetes, ischemic heart disease, hypertension, congestive cardiac failure, CHA2DS2-VASc (congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, stroke or transient ischemic attack (TIA), vascular disease, age 65 to 74 years, sex category) score a predictor of stroke risk in atrial fibrillation, AF type (paroxysmal vs persistent/permanent), family history of AF, thyroid disease, and alcohol excess. Paroxysmal AF was defined as an episode of AF self-terminating within 7 days. Other forms of AF were considered as persistent/permanent. Echocardiographic data, when available, were reviewed for patient ejection fraction, atrial size, and valvulopathies.All patients underwent a panel of commonly used OSA screening tools and full in-laboratory PSG as the diagnostic reference within a week of one another, in randomized order. Randomization was conducted using computer-generated random-number software. The presence and severity of OSA was assessed in all patients with AF. The diagnostic accuracy of each screening tool was compared to in-laboratory PSG for various levels of OSA severity. OSA screening tools were as follows: the presence of patient-reported snoring, obesity (body mass index ≥ 30 kg/m2), airway crowding (modified Mallampati score ≥ 3), self-reported daytime somnolence as measured by the Epworth Sleepiness Scale, the STOP-BANG questionnaire score, the Berlin questionnaire “high risk” category, and results from a level 3 portable home sleep apnea test (HSAT) (ApneaLink Air, ResMed Ltd, San Diego) performed in the patient’s home. Clinical screening tools are summarized in Table S1 in the supplemental material. Test characteristics (sensitivity, specificity, positive and negative predictive values, and receiver operating characteristic areas under the curve [AUC]) were compared with the results from PSG.PSGPSG was performed and analyzed in a single tertiary referral center by experienced technicians who were blinded to the screening tool results. PSG was scored according to American Academy of Sleep Medicine 2012 criteria.19 An apnea was defined as a complete (≥ 90%) reduction in airflow, lasting ≥ 10 seconds. A hypopnea was defined as a partial (≥ 30%) reduction in airflow, lasting ≥ 10 seconds, associated with either an arousal from sleep or an oxygen desaturation of ≥ 3% from baseline.Sleep apnea severity definitionsThe apnea-hypopnea index (AHI) is the primary metric used to classify sleep apnea severity. It is defined as the number of apneas plus hypopneas occurring per hour of sleep time (for PSG) or recording time (for level 3 or 4 devices that do not have electroencephalogram capability and are therefore unable to detect the presence of sleep). An AHI of 5 to < 15 events/h is classified as mild OSA, an AHI of 15 to < 30 events/h is classified as moderate OSA, and an AHI ≥ 30 events/h is classified as severe OSA.Level 3 portable sleep study deviceThe ApneaLink Air device (ResMed) is a portable, level 3 sleep study device comprising 4 channels: 1. heart rate, 2. oxygen saturation (both captured via pulse oximeter), 3. airflow via a nasal cannula pressure transducer, and 4. respiratory effort measured via a chest band with a pneumatic sensor. Application of the device was shown to patients in a clinic setting, after which patients were issued with a loan device to use overnight in their own home. Automated software analysis was used to derive sleep parameters including the AHI and a 3% oxygen desaturation index (ODI). The ODI, measured by pulse oximetry, is the average number of oxygen desaturations (3%) from baseline per hour of sleep time (for PSG) or recording time (for level 3 or 4 devices). ApneaLink automatic scoring software has previously shown good diagnostic accuracy compared with concurrent PSG in a sleep center population (AUC, 0.87; standard error, 0.06).20Patient-centered assessmentsA subset of patients (n = 29) completed paired visual analog questionnaires relating to patient-centered perceived qualities of in-laboratory PSG vs a level 3 portable sleep study device (questionnaire reproduced in Figure S1). Outcomes included test comfort, test convenience, perceived similarity to the patient’s usual sleep pattern during the test, and patient confidence in the test results.Statistical analysisData are presented as the mean ± standard deviation or as a percentage of the total group. Continuous variables were compared between dichotomous groups using independent t tests. The Levene test was used to assess the homogeneity of variances. Categorical variables were compared using χ2 tests or the Fisher exact test, as applicable. A P value of < .05 was considered statistically significant. Sensitivities, specificities, receiver operating characteristic curves, and positive and negative predictive values were calculated using the statistical software package IBM SPSS Statistics for Windows, Armonk, NY. Receiver operating characteristic AUC was used to assess diagnostic accuracy according to the following thresholds: excellent, 0.9–1.0; good, 0.8–0.9; fair, 0.7–0.8; poor, 0.6–0.7; very poor, 0.5–0.6.Sample size calculationSample size estimates were obtained by evaluating confidence intervals (CIs) for likelihood ratios for diagnostic test studies.21 We hypothesized that ApneaLink would be clinically useful as a screening tool if the upper limit of the CI for the negative likelihood ratio was no greater than 0.2. We used an estimated AF prevalence of 65%, based on a previous study of OSA in an Australian AF population (although the study was limited to patients with AF with a normal ejection fraction).4 The sensitivity and specificity for the ApneaLink device for the detection of moderate or severe OSA (AHI > 15) have been documented at 0.947 and 1.0, respectively, in a non-AF population.22 Therefore, we required at least 40 patients with OSA and 40 patients without OSA to complete the final analysis. Considering the expected prevalence of 65%, a total of 88 patients was required. To offset an expected withdrawal rate of up to 20%, we aimed to recruit a total of 110 patients for the study.RESULTSThe study flowchart is outlined in Figure 1. Baseline characteristics are summarized in Table 1 by the presence of moderate to severe OSA. Baseline characteristics are also reported in the supplemental material by recruitment stream (ED vs PVI, Table S2) and according to OSA of differing severities (Table S3 and Table S4). A Bland-Altman plot comparing AHI from PSG and from ApneaLink is presented in Figure S2.Table 1 Baseline characteristics of patients with AF with and without moderate to severe OSA (AHI ≥ 15 events/h).CharacteristicTotal (n = 107)AHI < 15/h (n = 74)AHI ≥ 15/h (n = 33)P ValueGeneral demographics Recruitment stream: ED58 (54.2)40 (54.1)18 (54.5).962 Age (y)61.3 ± 11.760.2 ± 12.163.88 ± 10.3.130 Male70 (65.4)45 (60.8)25 (75.8).133 Ethnicity: Caucasian99 (92.5)68 (91.2)31 (93.9).870Phenotypic characteristics BMI (kg/m2)27.2 ± 4.225.8 ± 3.330.4 ± 4.2< .001 Neck circumference, cm (n = 105)40.0 ± 4.739.1 ± 3.942.1 ± 5.8.003 Modified Mallampati score (n = 106)2.7 ± 0.92.5 ± 0.93.1 ± 0.7.001OSA symptoms ESS score6.1 (3.4)5.7 ± 3.36.9 ± 3.4.079 Self-reported snoring69 (64.5)43 (58.1)26 (78.8).039Comorbidities/AF risk factors Alcohol excess* (n = 105)26 (24.2)17 (23.3)9 (28.1).730 Thyroid disease17 (15.9)15 (20.3)2 (6.1).135 Family history of AF33 (30.8)27 (36.5)6 (18.9).015 Moderate-severe MS/prosthetic heart valve3 (2.8)2 (2.7)1 (3.0).865 Hypertension44 (41.1)22 (29.7)22 (66.7)< .001 Diabetes5 (4.7)2 (2.7)3 (9.1).169 IHD5 (4.7)2 (2.7)3 (9.1).169 CCF18 (16.8)8 (10.8)10 (30.3).013 Cerebrovascular disease2 (1.8)2 (2.7)0 (0).476 Peripheral vascular disease3 (2.8)3 (4.1)0 (0).327 CHA2DS2-VASc score1.6 ± 1.31.5 ± 1.22.0 ± 1.4.038AF characteristics Paroxysmal102 (95.3)73 (98.6)29 (87.9).015 Persistent/permanent5 (4.7)1 (1.4)4 (12.1).015 High burden†34 (31.8)24 (32.4)10 (30.3).827 Antiarrhythmic therapy88 (82.2)60 (81.0)28 (84.8).638 Anticoagulant therapy87 (81.3)60 (81.0)27 (81.8).730Echocardiographic parameters Cardiac ejection fraction, % (n = 79)57.5 ± 8.658.8 ± 7.754.6 ± 9.8.075 Left atrial diameter, cm (n = 57)4.1 ± 0.64.0 ± 0.64.3 ± 0.6.211 Left atrial area, cm2 (n = 50)24.3 ± 5.223.4 ± 5.226.6 ± 4.7.048Questionnaires Berlin high-risk score (n = 106)44 (41.5)19 (25.7)25 (75.8)< .001 STOP-BANG score3.5 ± 1.73.0 ± 1.34.7 ± 1.7< .001Sleep parameters: from PSG AHI13.5 ± 15.55.2 ± 4.331.9 ± 15.5< .001 ODI7.1 ± 10.62.1 ± 2.318.4 ± 13.1< .001 CAI0.6 ± 1.50.2 ± 0.51.4 ± 2.5< .001Values are presented as mean ± SD or n (%). *Ten or more standard drinks/week. †Ten or more episodes of AF in the last 12 months. AF = atrial fibrillation, AHI = apnea-hypopnea index, BMI = body mass index, CAI = central apnea index, CHA2DS2-VASc = (congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, stroke or transient ischemic attack (TIA), vascular disease, age 65 to 74 years, sex category), CCF = congestive cardiac failure, ED = emergency department, ESS = Epworth Sleepiness Scale, IHD = ischemic heart disease, MS = mitral stenosis, ODI = oxygen desaturation index, OSA = obstructive sleep apnea, PSG = polysomnography, PVI = pulmonary vein isolation procedure waitlist.OSA clinical screening toolsA level 3 HSAT was the only screening tool that performed with good to excellent diagnostic accuracy across all severity categories. AHI derived from a level 3 portable sleep study device performed best for the detection of OSA of any severity (AHI ≥ 5 events/h; AUC, 0.896; 95% CI, 0.830–0.961). ODI derived from a level 3 portable sleep study device performed best for the detection of moderate to severe OSA (AHI ≥ 15 events/h; AUC, 0.899; 95% CI, 0.838–0.960) and for severe OSA only (AHI ≥ 30 events/h; AUC, 0.925; 95% CI, 0.859–0.991).For moderate to severe OSA, snoring and self-reported hypersomnolence measured via the Epworth Sleepiness Scale both performed with poor diagnostic accuracy. Obesity, a modified Mallampati score ≥ 3, and a STOP-BANG or Berlin questionnaire score in the high-risk category performed with fair diagnostic accuracy.For severe OSA, 2 screening tools performed with good diagnostic accuracy: obesity (body mass index ≥ 30 kg/m2), with an AUC of 0.865 (95% CI, 0.741–0.990), and a STOP-BANG questionnaire score in the high-risk range (≥ 5; AUC, 0.847; 95% CI, 0.733–0.961). A Berlin questionnaire in the high-risk category performed with fair diagnostic accuracy, and snoring, self-reported hypersomnolence, and a modified Mallampati score ≥ 3 all performed with poor to very poor diagnostic accuracy.Across all severity categories, the presence of snoring was a highly sensitive but not specific tool for the detection of OSA, although overall the presence of snoring showed poor to very poor diagnostic accuracy. The Epworth Sleepiness Scale also showed poor to very poor diagnostic accuracy across all severity categories. Screening tool diagnostic accuracy characteristics are reported in Table 2 and in Figure 2.Table 2 Sensitivity and specificity of clinical OSA screening tools in an AF cohort, at various levels of OSA severity (n = 98).Any OSA (n = 64)Moderate to Severe OSA (n = 31)Severe OSA (n = 12)Sns (%)Spc (%)PPVNPVAUC (95% CI)Sns (%)Spc (%)PPVNPVAUC (95% CI)Sns (%)Spc (%)PPVNPVAUC (95% CI)Self-reported scoring78.150.074.654.80.641 (0.22–0.522)83.938.838.883.90.613 (0.498–0.729)83.333.814.993.50.585 (0.424–0.746)Obesity (BMI ≥ 30 kg/m2)32.894.191.342.70.732 (0.627–0.837)51.689.669.680.00.785 (0.686–0.883)83.384.943.597.30.865 (0.741–0.990)Modified Mallampati score ≥ 367.258.875.448.80.665 (0.548–0.782)80.652.243.985.40.708 (0.602–0.813)91.746.519.397.60.683 (0.554–0.812)Elevated ESS score (≥ 11)8.891.266.734.80.608 (0.487–0.730)16.194.055.670.80.615 (0.495–0.735)8.390.711.187.60.584 (0.441–0.726)STOP-BANG score, intermediate- to high-risk (≥ 3)77.638.568.450.00.580 (0.465–0.695)90.937.039.590.00.639 (0.532–0.747)92.331.215.896.70.617 (0.474–0.761)STOP-BANG score, high-risk (≥ 5)36.091.288.543.10.683 (0.579–0.787)58.188.169.282.00.787 (0.688–0.886)83.381.438.597.20.847 (0.733–0.961)Berlin questionnaire, high-risk56.376.581.848.10.664 (0.552–0.775)80.771.656.888.90.761 (0.659–0.864)83.360.522.796.30.719 (0.577–0.861)Level 3 sleep study: AHI Cutoff AHI, 5.15 events/h79.788.292.769.80.896 (0.830–0.961) Cutoff AHI, 8.75 events/h80.674.659.589.20.868 (0.799–0.937) Cutoff AHI, 10.95 events/h83.374.431.297.00.866 (0.774– 0.958)Level 3 sleep study: ODI Cutoff ODI, 4.9584.479.488.573.00.874 (0.799–0.948) Cutoff ODI, 8.3083.979.165.091.40.899 (0.838–0.960) Cutoff ODI, 13.7583.387.247.697.40.925 (0.859–0.991)Sensitivity and specificity values defined as excellent: 0.9–1.0, good: 0.8–0.9, fair: 0.7–0.8, poor: 0.6–0.7, and very poor: 0.5–0.6. OSA severity defined as: Any OSA (AHI ≥ 5/h), Moderate to severe OSA (AHI ≥ 15/h), Severe OSA (AHI ≥ 30/h). AF = atrial fibrillation, AHI = apnea-hypopnea index, AUC = area under the curve, BMI = body mass index, CI = confidence interval, ESS = Epworth Sleepiness Scale, NPV = negative predictive value, ODI oxygen desaturation index, OSA = obstructive sleep apnea, PPV = positive predictive value, Sns = sensitivity, Spc = specificity.Figure 2: ROC curves depicting the diagnostic accuracy of OSA screening tools at various levels of severity.A level 3 portable sleep study device had good to excellent diagnostic accuracy for all levels of OSA severity (AUC, 0.896–0.925). For moderate to severe OSA, snoring and self-reported hypersomnolence measured via the ESS both performed with poor diagnostic accuracy. All ROC AUC results are detailed in Table 2. AF = atrial fibrillation, AHI = apnea-hypopnea index, AUC = area under the curve, ESS = Epworth Sleepiness Scale, ODI = oxygen desaturation index, OSA = obstructive sleep apnea, ROC = receiver operating characteristic.Download FigurePatient-centered evaluation of sleep testsA level 3 HSAT was perceived by patients as significantly more comfortable, more convenient, and more conducive to replicating their usual sleep pattern when compared to in-laboratory PSG (Table 3). There was no difference in patient confidence in the test results.Table 3 Self-reported patient assessment of in-laboratory PSG vs a level 3 portable sleep study device at home.PSGLevel 3 DeviceMean Difference (95% CI)P ValueHow comfortable did you find the study?5.9 ± 2.47.2 ± 1.7−1.2 (−2.3 to −0.2).018How convenient did you find the study?7.0 ± 2.58.2 ± 1.1−1.3 (−2.2 to −0.4).008How closely did your sleep on the study night match your normal sleep pattern at home?5.1 ± 2.37.3 ± 2.1−2.2 (−3.3 to −1.1)< .001How confident were you in the results of the study?7.5 ± 1.97.5 ± 1.70.0 (−0.8 to 0.8).99Results from paired visual analog scales (1–10) in a subset of 29 patients. CI = confidence interval, PSG = polysomnography.OSA diagnosisWe found that 67 patients (62.6%) were newly diagnosed with OSA (31.8% mild, 18.7% moderate, 12.1% severe). The average AHI in the OSA group fell within the moderate range (20.4 ± 15.8 events/h). There was no significant difference in the presence of moderate to severe OSA between the ED and PVI recruitment streams (31.0% vs 30.1%; P = .962).DISCUSSIONThis is the first study to validate a level 3 HSAT (also known as polygraphy) in an AF population, indicating its superiority to other OSA screening tools. Overall, a level 3 HSAT showed the highest diagnostic accuracy at all levels of OSA severity: mild, moderate, and severe. Previously, these devices have been validated only in patients in sleep clinics or in patients suspected to have OSA.20,22–24 We have shown that patients with AF represent a distinct clinical phenotype when compared with a sleep clinic population and are less likely to have daytime symptoms or obesity, thus supporting the need and clinical relevance of test validation in the target population.Notably, many traditional OSA risk factors did not perform well as screening tools in this AF cohort, including some that are recommended in clinical guidelines. This finding gives caution to the use of self-reported snoring and daytime hypersomnolence, both of which performed with poor diagnostic accuracy for moderate to severe OSA and with very poor diagnostic accuracy for severe OSA. Similarly, the presence of obesity, which is linked to OSA treatment in the American Heart Association/American College of Cardiology/Heart Rhythm Society guidelines,16 performed with only fair diagnostic accuracy for moderate to severe OSA, whereas it performed with good diagnostic accuracy for severe OSA.Self-reported hypersomnolence via the Epworth Sleepiness Scale has been shown in 3 prior studies of patients with AF to be poorly predictive of OSA,25–27 although ours is the first study to report the diagnostic accuracy of self-reported snoring and obesity as OSA screening tools in an AF population against the gold standard of PSG.Diagnostic accuracy of questionnaires and patient-reported symptomsThis study adds to the very limited available data on the diagnostic accuracy of screening questionnaires in patients with AF. Both the STOP-BANG questionnaire scores ≥ 5 and the Berlin questionnaire overall performed with only fair diagnostic accuracy for moderate to severe OSA (AUC, 0.787; 95% CI; 0.688–0.886; AUC, 0.761; 95% CI, 0.659–0.864, respectively), results that are broadly consistent with a previously published study.27 The diminished performance of these questionnaires likely reflects the paucity of traditional OSA symptoms in an AF group.Despite an AUC of only 0.639, a STOP-BANG score ≥ 3 (intermediate to high risk) had a very high negative predictive value for the exclusion of moderate to severe OSA (negative predictive value, 90.0 for AHI ≥ 15 events/h). This characteristic in particular would make a STOP-BANG score ≥ 3 a useful screening tool for regional or underresourced areas where a level 3 device may not be accessible. In addition, the high negative predictive value lends itself to a tiered screening strategy whereby STOP-BANG could be utilized initially, followed by a level 3 device for those patients with a STOP-BANG score ≥ 3. For every 100 patients screened with this approach, 29 would return a negative STOP-BANG result and therefore could forego the ApneaLink test. However, for every 100 patients screened with this tiered strategy, 3 patients with an AHI > 15 events/h would be missed.Some screening tools, notably the presence of obesity, performed differently across different levels of OSA severity. This finding raises the question of what level of OSA severity is clinically significant in AF, an issue that is confounded by variable OSA definitions and diagnostic methods in the literature to date. The significance of OSA severity in patients with AF is an area for future research.Level 3 HSAT (polygraphy) vs overnight oximetryIn this study, ODI and AHI were derived from a level 3 portable sleep study device. Two prior studies assessed ODI from overnight oximetry alone as a screening tool for OSA in patients with cardiac concerns, including 1 study in an AF population.28,29 In a group of 439 patients with AF, Linz et al28 showed an AUC of 0.951 (95% CI, 0.929–0.972) for the detection of moderate to se

Referência(s)