Comparative Study Between Sensitization Degree of the 0.4% Mo Austenitic Stainless Steel and UNS S31803 Duplex Stainless Steel
2021; Associação Brasileira de Metalurgia e Materiais (ABM); Associação Brasileira de Cerâmica (ABC); Associação Brasileira de Polímer; Volume: 24; Issue: 1 Linguagem: Inglês
10.1590/1980-5373-mr-2020-0408
ISSN1980-5373
AutoresJosé Carlos de Lacerda, Lucas L. de Freitas, Rogério Fernandes Brito, F. Moura, Ricardo Luiz Perez Teixeira,
Tópico(s)Concrete Corrosion and Durability
ResumoThis study aims at assessing the degree of susceptibility to intergranular corrosion of the UNS S31803 duplex stainless steel and the 0.4% Mo austenitic stainless steel through the double-loop electrochemical potentiodynamic reactivation (DL-EPR) test. Both steels were subjected to isothermal treatments at 650ºC and 900ºC in order to compare the effect of temperature on the respective degrees of sensitization. It was observed that the 0.4% Mo austenitic stainless steel presented a higher degree of sensitization and, consequently, a greater susceptibility to the intergranular corrosion process when compared to the UNS S31803 duplex stainless steel in the two temperatures studied. It was also observed that, for both steels, the heat treatment at 900ºC resulted in a higher degree of sensitization when compared to the heat treatment at 650ºC.
Referência(s)