Artigo Revisado por pares

Current Awareness in NMR in Biomedicine

2006; Wiley; Volume: 19; Issue: 3 Linguagem: Inglês

10.1002/nbm.1056

ISSN

1099-1492

Tópico(s)

Advanced NMR Techniques and Applications

Resumo

NMR in BiomedicineVolume 19, Issue 3 p. 401-408 Current AwarenessFree Access Current Awareness in NMR in Biomedicine First published: 16 May 2006 https://doi.org/10.1002/nbm.1056AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onFacebookTwitterLinkedInRedditWechat Abstract In order to keep subscribers up-to-date with the latest developments in their field, John Wiley & Sons are providing a current awareness service in each issue of the journal. The bibliography contains newly published material in the field of NMR in biomedicine. Each bibliography is divided into 11 sections: 1 Books, Reviews ' Symposia; 2 General; 3 Technology; 4 Contrast Agents; 5 Brain and Nerves; 6 Neuropathology; 7 Cancer; 8 Cardiac, Vascular and Respiratory Systems; 9 Liver, Kidney and Other Organs; 10 Muscle and Orthopaedic; 11 Plants, Micro-organisms and Parasites; 12 Others. Within each section, articles are listed in alphabetical order with respect to author. If, in the preceding period, no publications are located relevant to any one of these headings, that section will be omitted. Current Awareness 1. Books, Reviews ' Symposia Baur-Melnyk A, Buhmann S, Durr HR, Reiser M. Role of MRI for the diagnosis and prognosis of multiple myeloma. Eur J Radiol 55, 56-63 (2005) Bellin MF, Webb JAW, Van der Molen AJ, Thomsen HS, Morcos SK. Safety of MR liver specific contrast media. Eur Radiol 15, 1607-1614 (2005) Bolan PJ, Nelson MT, Yee D, Garwood M. Imaging in breast cancer: Magnetic resonance spectroscopy. Breast Cancer Res 7, 149-152 (2005) De Stefano N, Bartolozzi ML, Guidi L, Stromilloa ML, Federico A. Magnetic resonance spectroscopy as a measure of brain damage in multiple sclerosis. J Neurol Sci 233, 203-208 (2005) Fuster V, Kim RJ. Frontiers in cardiovascular magnetic resonance. Circulation 112, 135-144 (2005) Ghanem N, Uhl M, Brink I, Schafer O, Kelly T, Moser E, Langer M. Diagnostic value of MRI in comparison to scintigraphy, PET, MS-CT and PET/CT for the detection of metastases of bone. Eur J Radiol 55, 41-55 (2005) Horsthuis K, Lavini C, Stoker J. MRI in Crohns disease (CHECK 1). J Magn Reson Imaging 22, 1-12 (2005) Kruit MC, Launer LJ, Van Buchem MA, Terwindt GM, Ferrari MD. MRI findings in migraine (French, English Abstract). Rev Neurol (Paris) 161, 661-665 (2005) Lombardi M, Aquaro G, Favilli B. Contrast media in cardiovascular magnetic resonance. Curr Pharm Des 11, 2151-2161 (2005) Luna A, Ribes R, Caro P, Vida J, Erasmus JJ. Evaluation of cardiac tumors with magnetic resonance imaging. Eur Radiol 15, 1446-1455 (2005) Lurie DJ, Mader K. Monitoring drug delivery processes by EPR and related techniques - Principles and applications. Adv Drug Deliv Rev 57, 1171-1190 (2005) Nobauer I, Uffmann M. Differential diagnosis of focal and diffuse neoplastic diseases of bone marrow in MRI. Eur J Radiol 55, 2-32 (2005) Richardson JC, Bowtell RW, Mader K, Melia CD. Pharmaceutical applications of magnetic resonance imaging (MRI). Adv Drug Deliv Rev 57, 1191-1209 (2005) Yu AH, Li KC, Piao CF, Li HL. Application of functional MRI in epilepsy. Chin Med J (Engl) 118, 1022-1027 (2005) Zwingmann C, Butterworth R. An update on the role of brain glutamine synthesis and its relation to cell-specific energy metabolism in the hyperammonemic brain: Further studies using NMR spectroscopy. Neurochem Int 47, 19-30 (2005) 3. Technology Barry RL, Menon RS. Modeling and suppression of respiration-related physiological noise in echo-planar functional magnetic resonance imaging using global and one-dimensional navigator echo correction. Magn Reson Med 54, 411-418 (2005) Bieri O, Markl M, Scheffler K. Analysis and compensation of eddy currents in balanced SSFP. Magn Reson Med 54, 129-137 (2005) Blank A, Alexandrowicz G, Muchnik L, Tidhar G, Schneiderman J, Virmani R, 'Golan E. Miniature self-contained intravascular magnetic resonance (IVMI) probe for clinical applications. Magn Reson Med 54, 105-112 (2005) Carmichael DW, Priest AN, De Vita E, Ordidge RJ. Common SENSE (sensitivity encoding using hardware common to all MR scanners): A new method for single-shot segmented echo planar imaging. Magn Reson Med 54, 402-410 (2005) Chen B, Hsu EW. Noise removal in magnetic resonance diffusion tensor imaging. Magn Reson Med 54, 393-401 (2005) Crockford DJ, Keun HC, Smith LM, Holmes E, Nicholson JK. Curve-fitting method for direct quantitation of compounds in complex biological mixtures using 1H NMR: Application in metabonomic toxicology studies. Anal Chem 77, 4556-4562 (2005) Dreher W, Leibfritz D. New method for the simultaneous detection of metabolites and water in localized in vivo 1H nuclear magnetic resonance spectroscopy. Magn Reson Med 54, 190-195 (2005) Galons JP, Lope-Piedrafita S, Divijak JL, Corum C, Gillies RJ, Trouard TP. Uncovering of intracellular water in cultured cells. Magn Reson Med 54, 79-86 (2005) Garcia DM, Duhamel G, Alsop DC. Efficiency of inversion pulses for background suppressed arterial spin labeling. Magn Reson Med 54, 366-372 (2005) Goldfarb JW, Arnold S, Schapiro W, Reichek N. On the cause of spatial displacement of long T1 species in segmented inversion recovery prepared imaging. Magn Reson Med 54, 481-485 (2005) Graf H, Steidle G, Martirosian P, Lauer UA, Schick F. Metal artifacts caused by gradient switching. Magn Reson Med 54, 231-234 (2005) Grinstead J, Sinha S. In-plane velocity encoding with coherent steady-state imaging. Magn Reson Med 54, 138-145 (2005) Gunther M, Oshio K, Feinberg DA. Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements. Magn Reson Med 54, 491-498 (2005) Hancu I, Blezek DJ, Dumoulin MC. Automatic repositioning of single voxels in longitudinal 1H MRS studies. NMR Biomed 18, 352-361 (2005) Hershey BL, Doyle M, Kortright E, More R, Rayarao G, Anayiotos A. Extension of rapid phase-contrast magnetic resonance imaging using BRISK in multidirectional flow. Ann Biomed Eng 33, 929-936 (2005) Hu HH, Madhuranthakam AJ, Kruger DG, Glockner JF, Riederer SJ. Variable field of view for spatial resolution improvement in continuously moving table magnetic resonance imaging. Magn Reson Med 54, 146-151 (2005) Ibrahim TS, Kangarlu A, Chakeress DW. Design and performance issues of RF coils utilized in ultra high field MRI: Experimental and numerical evaluations. IEEE Trans Biomed Eng 52, 1278-1284 (2005) Kinchesh P, Ordidge RJ. Spin-echo MRS in humans at high field: LASER localisation using FOCI pulses. J Magn Reson 175, 30-43 (2005) Lee KJ, Paley MNJ, Griffiths PD, Wild JM. Method of generalized projections algorithm for image-based reduction of artifacts in radial imaging. Magn Reson Med 54, 246-250 (2005) Lin FH, Huang TY, Chen NK, Wang FN, Stufflebeam SM, Belliveau JW, Wald LL, Kwong KK. Functional MRI using regularized parallel imaging acquisition. Magn Reson Med 54, 343-353 (2005) Liu CL, Bammer R, Moseley ME. Limitations of apparent diffusion coefficient-based models in characterizing non-Gaussian diffusion. Magn Reson Med 54, 419-428 (2005) Liu F, Beck BL, Xu B, Fitzsimmons JR, Blackband SJ, Crozier S. Numerical modeling of 11.1T MRI of a human head using a MoM/FDTD method. Concepts Magn Reson Part B 24B, 28-38 (2005) Martin RW, Jachmann RC, Sakellariou D, Nielsen UG, Pines A. High-resolution nuclear magnetic resonance spectroscopy of biological tissues using projected magic angle spinning. Magn Reson Med 54, 253-257 (2005) Matsumoto S, Utsumi H, Aravalluvan T, Matsumoto K, Matsumoto A, Devasahayam N, Sowers AL, Mitchell JB, Subramanian S, Krishna MC. Influence of proton T1 on oxymetry using Overhauser enhanced magnetic resonance imaging. Magn Reson Med 54, 213-217 (2005) McDougall MP, Wright SM. 64-channel array coil for single echo acquisition magnetic resonance imaging. Magn Reson Med 54, 386-392 (2005) Moelker A, Maas RAJJ, Vogel MW, Ouhlous M, Pattynama PMT. Importance of bone-conducted sound transmission on patient hearing in the MR scanner. J Magn Reson Imaging 22, 163-169 (2005) Muresan L, Renken R, Roerdink JBTM, Duifhuis H. Automated correction of spin-history related motion artefacts in fMRI: Simulated and phantom data. IEEE Trans Biomed Eng 52, 1450-1460 (2005) Panych LP, Zhao L, Mulkern RV. PSF-Choice: A novel MRI method for shaping point-spread functions in phase-encoding dimensions. Magn Reson Med 54, 159-168 (2005) Qiu BS, El-Sharkawy AM, Paliwal V, Karmarkar P, Gao FB, Atalar E, Yang XM. Simultaneous radiofrequency (RF) heating and magnetic resonance (MR) thermal mapping using an intravascular MR imaging/RF heating system. Magn Reson Med 54, 226-230 (2005) Reeder SB, Markl M, Yu HZ, Hellinger JC, Herfkens RJ, Pelc NJ. Cardiac CINE imaging with IDEAL water-fat separation and steady-state free precession. J Magn Reson Imaging 22, 44-53 (2005) Rieseberg S, Merboldt KD, Kuntzel M, Frahm J. Diffusion tensor imaging using partial Fourier STEAM MRI with projection onto convex subsets reconstruction. Magn Reson Med 54, 486-490 (2005) Sandgren N, Stoica P, Frigo FJ, Selen Y. Spectral analysis of multichannel MRS data. J Magn Reson 175, 79-91 (2005) Sarty GE, Borowsky R. Functional MRI activation maps from empirically defined curve fitting. Concepts Magn Reson Part B 24B, 46-55 (2005) Skare S, Andersson JLR. Correction of MR image distortions induced by metallic objects using a 3D cubic B-spline basis set: Application to stereotactic surgical planning. Magn Reson Med 54, 169-181 (2005) So PW, Hotee S, Herlihy AH, Bell JD. Generic method for imaging transgene expression. Magn Reson Med 54, 218-221 (2005) Sun PZ, Zhou JY, Sun WY, Huang J, Van Zijl PCM. Suppression of lipid artifacts in amide proton transfer imaging. Magn Reson Med 54, 222-225 (2005) Sutton BP, Ciobanu L, Zhang XZ, Webb A. Parallel imaging for NMR microscopy at 14.1 Tesla. Magn Reson Med 54, 9-13 (2005) Weiss S, Vernickel P, Schaeffter T, Schulz V, Gleichl B. Transmission line for improved RF safety of interventional devices. Magn Reson Med 54, 182-189 (2005) Yeh EN, Stuber M, McKenzie CA, Botnar RM, Leiner T, Ohliger MA, Grant AK, Willig-Onwuachi JD, Sodickson DK. Inherently self-calibrating non-cartesian parallel imaging. Magn Reson Med 54, 1-8 (2005) Zhang Y, Song HK, Wang JJ, Techawiboonwong A, Wehrli FW. Spatially-confined arterial spin-labeling with FAIR. J Magn Reson Imaging 22, 119-124 (2005) 4. Contrast Agents Arbab AS, Wilson LB, Ashari P, Jordan EK, Lewis BK, Frank JA. A model of lysosomal metabolism of dextran coated superparamagnetic iron oxide (SPIO) nanoparticles: Implications for cellular magnetic resonance imaging. NMR Biomed 18, 383-389 (2005) Grazioli L, Morana G, Kirchin MA, Schneider G. Accurate differentiation of focal nodular hyperplasia from hepatic adenoma at gadobenate dimeglumine-enhanced MR imaging: Prospective study. Radiology 236, 166-177 (2005) Joe BN, Chen VY, Salibi N, Fuangtharntip P, Hildebolt CF, Bae KT. Evaluation of 1H-magnetic resonance spectroscopy of breast cancer pre- and postgadolinium administration. Invest Radiol 40, 405-411 (2005) Krombach GA, Higgins CB, Chujo M, Saeed M. Gadomer-enhanced MR imaging in the detection of microvascular obstruction: Alleviation with nicorandil therapy. Radiology 236, 510-518 (2005) Laus S, Sour A, Ruloff R, Toth E, Merbach AE. Rotational dynamics account for pH-dependent relaxatives of PAMAM dendrimeric, Gd-based potential MRI contrast agents. Chem-Eur J 11, 3064-3076 (2005) Lim JS, Kim MJ, Lim JH, Kim SI, Choi JS, Park MS, Oh YT, Yoo HS, Lee JT, Kim KW. Preoperative MRI of potential living-donor-related liver transplantation using a single dose of gadobenate dimeglumine. Am J Roentgenol 185, 424-431 (2005) Moon JC, Mogensen J, Elliott PM, Smith GC, Elkington AG, Prasad SK, Pennell DJ, McKenna WJ. Myocardial late gadolinium enhancement cardiovascular magnetic resonance in hypertrophic cardiomyopathy caused by mutations in troponin I. Heart 91, 1036-1040 (2005) Nijenhuis RJ, Gerretsen S, Leiner T, Jacobs MJ, Van Engelshoven JMA, Backes WH. Comparison of 0.5-M Gd-DTPA with 1.0-M gadobutrol for magnetic resonance angiography of the supplying arteries of the spinal cord in thoracoabdominal aortic aneurysm patients. J Magn Reson Imaging 22, 136-144 (2005) Parac-Vogt TN, Kimpe K, Laurent S, Vander Elst L, Burtea C, Chen F, Muller RN, Ni YC, Verbruggen A, Binnemans K. Synthesis, characterization, and pharmacokinetic evaluation of a potential MRI contrast agent containing two paramagnetic centers with albumin binding affinity. Chem Eur J 11, 3077-3086 (2005) Perez-Sanchez JM, De Alejo RP, Rodriguez I, Cortijo M, Peces-Barba G, Ruiz-Cabello J. In vivo diffusion weighted 19F MRI using SF6. Magn Reson Med 54, 460-463 (2005) Staatz G, Spuntrup E, Klosterhalfen B, Misselwitz B, Pfluger D, Gunther RW, Bucker A. High-resolution T1-weighted MRI of inguinal lymph nodes after interstitial MR-lymphography with Gadomer-17: Initial results in pigs (German, English Abstract). Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 177, 968-974 (2005) Van den Dool SW, Wasser MN, De Fijter JW, Hoekstra J, Van der Geest RJ. Functional renal volume: Quantitative analysis at gadolinium-enhanced MR angiography - Feasibility study in healthy potential kidney donors. Radiology 236, 189-195 (2005) 5. Brain and Nerves Algaze A, Leguire LE, Roberts C, Ibinson JW, Lewis JR, Rogers G. The effects of L-dopa on the functional magnetic resonance imaging response of patients with amblyopia: A pilot study. J AAPOS 9, 216-223 (2005) Anand A, Li Y, Wang Y, Wu JW, Gao SJ, Bukhari L, Mathews VP, Kalnin A, Lowe MJ. Antidepressant effect on connectivity of the mood-regulating circuit: An fMRI study. Neuropsychopharmacology 30, 1334-1344 (2005) Andrews T, Lancaster JL, Dodd SJ, Contreras-Sesvold C, Fox PT. Testing the three-pool white matter model adapted for use with T2 relaxometry. Magn Reson Med 54, 449-454 (2005) Assaf Y, Basser PJ. Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain. Neuroimage 27, 48-58 (2005) Baslow MH, Dyakin VV, Nowak KL, Hungund BL, Guilfoyle DN. 2-PMPA, a NAAG peptidase inhibitor, attenuates magnetic resonance BOLD signals in brain of anesthetized mice - Evidence of a link between neuron NAAG release and hyperemia. J Mol Neurosci 26, 1-15 (2005) Birn RM, Bandettini PA. The effect of stimulus duty cycle and “off” duration on BOLD response linearity. Neuroimage 27, 70-82 (2005) Brinkley CK, Kolodny NH, Kohler SJ, Sandeman DC, Beltz BS. Magnetic resonance imaging at 9.4 T as a tool for studying neural anatomy in non-vertebrates. J Neurosci Methods 146, 124-132 (2005) Calvo-Merino B, Glaser DE, Grezes J, Passingham RE, Haggard P. Action observation and acquired motor skills: An fMRI study with expert dancers. Cereb Cortex 15, 1243-1249 (2005) Chiu CYP, Coen-Cummings M, Schmithorst VJ, Holland SK, Keith R, Nabors L, Kramer M, Rozier H. Sound blending in the brain: A functional magnetic resonance imaging investigation. Neuroreport 16, 883-886 (2005) Choi CH, Coupland NJ, Hanstock CC, Ogilvie CJ, Higgins ACM, Gheorghiu D, Allen PS. Brain γ-aminobutyric acid measurement by proton double-quantum filtering with selective J rewinding. Magn Reson Med 54, 272-279 (2005) Cohen Kadosh R, Henik A, Rubinsten O, Mohr H, Dori H, Van de Ven V, Zorzi M, Hendler T, Goebel R, Linden DEJ. Are numbers special? The comparison systems of the human brain investigated by fMRI. Neuropsychologia 43, 1238-1248 (2005) Connolly JD, Goodale MA, Goltz HC, Munoz DP. fMRI activation in the human frontal eye field is correlated with saccadic reaction time. J Neurophysiol 94, 605-611 (2005) Deichmann R. Fast high-resolution T1 mapping of the human brain. Magn Reson Med 54, 20-27 (2005) Denslow S, Bohning DE, Bohning PA, Lomarev MP, George MS. An increased precision comparison of TMS-induced motor cortex BOLD fMRI response for image-guided versus function-guided coil placement. Cogn Behav Neurol 18, 119-126 (2005) Deoni SCL, Josseau MJC, Rutt BK, Peters TM. Visualization of thalamic nuclei on high resolution, multi-averaged T1 and T2 maps acquired at 1.5T. Hum Brain Mapp 25, 353-359 (2005) Dong Y, Nakamura K, Okada T, Hanakawa T, Fukuyama H, Mazziotta JC, Shibasaki H. Neural mechanisms underlying the processing of Chinese words: An fMRI study. Neurosci Res 52, 139-145 (2005) Eger E, Schweinberger SR, Dolan RJ, Henson RN. Familiarity enhances invariance of face representations in human ventral visual cortex: fMRI evidence. Neuroimage 26, 1128-1139 (2005) Federico P, Abbott DF, Briellmann RS, Harvey AS, Jackson GD. Functional MRI of the pre-ictal state. Brain 128, 1811-1817 (2005) Ferretti A, Caulo M, Del Gratta C, Di Matteo R, Merla A, Montorsi F, Pizzella V, Pompa P, Rigatti P, Rossini PM, Salonia A, Tartaro A, Romani GL. Dynamics of male sexual arousal: Distinct components of brain activation revealed by fMRI. Neuroimage 26, 1086-1096 (2005) Ford KA, Goltz HC, Brown MRG, Everling S. Neural processes associated with antisaccade task performance investigated with event-related fMRI. J Neurophysiol 94, 429-440 (2005) Gautama T, Van Hulle MM. Estimating the global order of the fMRI noise model. Neuroimage 26, 1211-1217 (2005) Gitelman DR, Nobre AC, Sonty S, Parrish TB, Mesulam MM. Language network specializations: An analysis with parallel task designs and functional magnetic resonance imaging. Neuroimage 26, 975-985 (2005) Grohn HI, Michaeli S, Garwood M, Kauppinen RA, Grohn OHJ. Quantitative T1ρ and adiabatic Carr-Purcell T2 magnetic resonance imaging of human occipital lobe at 4 T. Magn Reson Med 54, 14-19 (2005) Hawley ML, Melcher JR, Fullerton BC. Effects of sound bandwidth of fMRI activation in human auditory brainstem nuclei. Hear Res 204, 101-110 (YR) Henry ME, Schmidt ME, Hennen J, Villafuerte RA, Butman ML, Tran P, Kerner LT, Cohen B, Renshaw PF. A comparison of brain and serum pharmacokinetics of R-fluoxetine and racemic fluoxetine: A 19F MRS study. Neuropsychopharmacology 30, 1576-1583 (2005) Hoenig K, Scheef L. Mediotemporal contributions to sematic processing: fMRI evidence from ambiguity processing during semantic context verification. Hippocampus 15, 597-609 (2005) Hong BM, Pearlson GD, Calhoun VD. Source density-driven independent component analysis approach for fMRI data. Hum Brain Mapp 25, 297-307 (2005) Horwitz B, Warner B, Fitzer J, Tagamets MA, Husain FT, Long TW. Investigating the neural basis for functional and effective connectivity. Application to fMRI. Philos Trans R Soc Lond B 360, 1093-1108 (2005) Ikonomidou VN, Van Gelderen P, De Zwart JA, Fukunaga M, Duyn JH. Optimizing brain tissue contrast with EPI: A simulated annealing approach. Magn Reson Med 54, 373-385 (2005) Katz-Brull R, Koudinov AR, Degani H. Direct detection of brain acetylcholine synthesis by magnetic resonance spectroscopy. Brain Res 1048, 202-210 (2005) Katzir T, Misra M, Poldrack RA. Imaging phonology without print: Assessing the neural correlates of phonemic awareness using fMRI. Neuroimage 27, 106-115 (2005) Kerssens C, Hamann S, Peltier S, Hu XPP, Byas-Smith MG, Sebel PS. Attenuated brain response to auditory word stimulation with sevoflurane - A functional magnetic resonance imaging study in humans. Anesthesiology 103, 11-19 (2005) Kurata J, Thulborn KR, Firestone LL. The cross-modal interaction between pain-related and saccade-related cerebral activation: A preliminary study by event-related functional magnetic resonance imaging. Anesth Analg 101, 449-456 (2005) Lu HZ, Nagae-Poetscher LM, Golay X, Lin D, Pomper M, Van Zijl PCM. Routine clinical brain MRI sequences for use at 3.0 Tesla. J Magn Reson Imaging 22, 13-22 (2005) Lund TE, Norgaard MD, Rostrup E, Rowe JB, Paulson OB. Motion or activity: Their role in intra- and inter-subject variation in fMRI. Neuroimage 26, 960-964 (2005) Magnitsky S, Watson DJ, Walton RM, Pickup S, Bulte JWM, Wolfe JH, Poptani H. In vivo and ex vivo MRI detection of localized and disseminated neural stem cell grafts in the mouse brain. Neuroimage 26, 744-754 (2005) Maguire EA, Frith CD, Rudge P, Cipolotti L. The effect of adult-acquired hippocampal damage on memory retrieval: An fMRI study. Neuroimage 27, 146-152 (2005) Mayer D, Spielman DM. Detection of glutamate in the human brain at 3 T using optimized constant time point resolved spectroscopy. Magn Reson Med 54, 439-442 (2005) Meara SJP, Barker GJ. Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: Application to fluid-attenuated inversion-recovery and double inversion-recovery sequences. Magn Reson Med 54, 241-245 (2005) Meyer M, Zysset S, Von Cramon DY, Alter K. Distinct fMRI responses to laughter, speech, and sounds along the human peri-sylvian cortex. Brain Res Cogn Brain Res 24, 291-306 (2005) Milham MP, Banich MT. Anterior cingulate cortex: An fMRI analysis of conflict specificity and functional differentiation. Hum Brain Mapp 25, 328-335 (2005) Mostert JP, Sijens PE, Oudkerk M, De Keyser J. 1H Magnetic resonance spectroscopy of the internal capsule in human brain: A feasibility study to detect lactate following contralateral motor activity. Eur Radiol 15, 1349-1352 (2005) Nossin-Manor R, Duvdevani R, Cohen Y. Effect of experimental parameters on high b-value q-space MR images of excised rat spinal cord. Magn Reson Med 54, 96-104 (2005) O'Hara JA, Hou HG, Demidenko E, Springett RJ, Khan N, Swartz HM. Simultaneous measurement of rat brain cortex PtO2 using EPR oximetry and a fluorescence fiber-optic sensor during normoxia and hyperoxia. Physiol Meas 26, 203-213 (2005) Pinkerton RG, Barberi EA, Menon RS. Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T. Magn Reson Med 54, 499-503 (2005) Riedel E, Stephan T, Deutschlander A, Kalla R, Wiesmann M, Dieterich M, Brandt T. Imaging the visual autokinetic illusion with fMRI. Neuroimage 27, 163-166 (2005) Riera J, Aubert E, Iwata K, Kawashima R, Wan X, Ozaki T. Fusing EEG and fMRI based on a bottom-up model: Inferring activation and effective connectivity in neural masses. Philos Trans R Soc Lond B 360, 1025-1041 (2005) Rimol LM, Specht K, Weis S, Savoy R, Hugdahl K. Processing of sub-syllabic speech units in the posterior temporal lobe: An fMRI study. Neuroimage 26, 1059-1067 (2005) Rodd JM, Davis MH, Johnsrude IS. The neural mechanisms of speech comprehension: fMRI studies of semantic ambiguity. Cereb Cortex 15, 1261-1269 (2005) Rohde GK, Barnett AS, Basser PJ, Pierpaoli C. Estimating intensity variance due to noise in registered images: Applications to diffusion tensor MRI. Neuroimage 26, 673-684 (2005) Ronen I, Ugurbil K, Kim DS. How does DWI correlate with white matter structures?. Magn Reson Med 54, 317-323 (2005) Rosen AC, Gabrieli JDE, Stoub T, Prull MW, O'Hara R, Yesavage J, DeToledo-Morrell L. Relating medical temporal lobe volume to frontal fMRI activation for memory encoding in older adults. Cortex 41, 595-602 (2005) Rypma B, Berger JS, Genova HM, Rebbechi D, D'Esposito M. Dissociating age-related changes in cognitive strategy and neural efficiency using event-related fMRI. Cortex 41, 582-594 (2005) Schafer JR, Kida I, Rothman DL, Hyder F, Xu FQ. Adaptation in the rodent olfactory bulb measured by fMRI. Magn Reson Med 54, 443-448 (2005) Schmidt CF, Boesiger P, Ishai A. Comparison of fMRI activation as measured with gradient- and spin-echo EPI during visual perception. Neuroimage 26, 852-859 (2005) Smith SA, Golay X, Fatemi A, Jones CK, Raymond GV, Moser HW, Van Zijl PCM. Magnetization transfer weighted imaging in the upper cervical spinal cord using cerebrospinal fluid as intersubject normalization reference (MTCSF imaging). Magn Reson Med 54, 201-206 (2005) Stephan T, Deutschlander A, Nolte A, Schneider E, Wiesmann M, Brandt T, Dieterich M. Functional MRI of galvanic vestibular stimulation with alternating currents at different frequencies. Neuroimage 26, 721-732 (2005) Stuckey DJ, Anthony DC, Lowe JP, Miller J, Palm WM, Styles P, Perry VH, Blamire AM, Sibson NR. Detection of the inhibitory neurotransmitter GABA in macrophages by magnetic resonance spectroscopy. J Leukoc Biol 78, 393-400 (2005) Sweet LH, Paskavitz JF, O'Connor MJ, Browndyke JN, Wellen JW, Cohen RA. fMRI correlates of the WAIS-III Symbol Search subtest. J Int Neuropsychol Soc 11, 471-476 (2005) Van der Kouwe AJW, Benner T, Fischl B, Schmitt F, Salat DH, Harder M, Sorensen AG, Dale AM. On-line automatic slice positioning for brain MR imaging. Neuroimage 27, 222-230 (2005) Vanni S, Henriksson L, James AC. Multifocal fMRI mapping of visual cortical areas. Neuroimage 27, 95-105 (2005) Wehrle R, Czisch M, Kaufmann C, Wetter TC, Holsboer F, Auer DP, Pollmacher T. Rapid eye movement-related brain activation in human sleep: A functional magnetic resonance imaging study. Neuroreport 16, 853-857 (2005) Wiggins GC, Potthast A, Triantafyllou C, Wiggins CJ, Wald LL. Eigh'-channel phased array coil and detunable TEM volume coil for 7 T brain imaging. Magn Reson Med 54, 235-240 (2005) Wraga M, Shephard JM, Church JA, Inati S, Kosslyn SM. Imagined rotations of self versus objects: An fMRI study. Neuropsychologia 43, 1351-1361 (2005) Yan B, Li K, Xu JY, Wang W, Li KC, Liu H, Shan BC, Tang XW. Acupoint-specific fMRI patterns in human brain. Neurosci Lett 383, 236-240 (2005) Yang SL, Ross TJ, Zhang YQ, Stein EA, Yang YH. Head motion suppression using real-time feedback of motion information and its effects on task performance in fMRI. Neuroimage 27, 153-162 (2005) Yong-Hing CJ, Obenaus A, Stryker R, Tong K, Sarty GE. Magnetic resonance imaging and mathematical modeling of progressive formalin fixation of the human brain. Magn Reson Med 54, 324-332 (2005) Yoo SS, O'Leary HM, Dickey CC, Wei XC, Guttmann CRG, Park HW, Panych LP. Functional asymmetry in human primary auditory cortex: Identified from longitudinal fMRI study. Neurosci Lett 383, 1-6 (2005) Yu X, Wadghiri YZ, Sanes DH, Turnbull DH. In vivo auditory brain mapping in mice with Mn-enhanced MRI. Nat Neurosci 8, 961-968'(2005) Zaharchuk G, Martin AJ, Rosenthal G, Manley GT, Dillon WP. Measurement of cerebrospinal fluid oxygen partial pressure in humans using MRI. Magn Reson Med 54, 113-121 (2005) Zhang NY, Zhu XH, Chen W. Influence of gradient acoustic noise on fMRI response in the human visual cortex. Magn Reson Med 54, 258-263 (2005) Zou P, Hutchins SB, Dutkiewicz RM, Li CS, Ogg RJ. Effects of EPI readout bandwidth on measured activation map and BOLD response in fMRI experiments. Neuroimage 27, 15-25 (2005) 6. Neuropathology Alexander JJ, Zwingmann C, Quigg R. MRLsol;lpr mice have alterations in brain metabolism as shown with [1H-13C] NMR spectroscopy. Neurochem Int 47, 143-151 (2005) Binder JR, Bellgowan PSF, Hammeke TA, Possing ET, Frost JA. A comparison of two fMRI protocols for eliciting hippocampal activation. Epilepsia 46, 1061-1070 (2005) Birbaumer N, Viet R, Lotze M, Erb M, Hermann C, Grodd W, Flor H. Deficient fear conditioning in psychopathy - A functional magnetic resonance imaging study. Arch Gen Psychiatry 62, 799-805 (2005) Bryant RA, Felmingham KL, Kemp AH, Barton M, Peduto AS, Rennie C, Gordon E, Williams LM. Neural networks of information processing in posttraumatic stress disorder: A functional magnetic resonance imaging study. Biol Psychiatry

Referência(s)
Altmetric
PlumX