Artigo Revisado por pares

Update of the BIPM comparison BIPM.RI(II)-K1.Co-60 of activity measurements of the radionuclide 60 Co to include the 2020 result of the PTB (Germany), the 2020 result of the NIST (United States), the 2020 result of the SMU (Slovakia), the 2021 result of the BARC (India), the 2021 result of the LNE-LNHB (France), the 2021 result of the POLATOM (Poland), the 2021 result of the ENEA-INMRI (Italy), the 2021 result of the NPL (United Kingdom), the 2021 result of the LNMRI-IRD (Brazil), the…

2023; IOP Publishing; Volume: 60; Issue: 1A Linguagem: Inglês

10.1088/0026-1394/60/1a/06010

ISSN

1681-7575

Autores

Romain Coulon, C Michotte, S Courte, Manuel Nonis, W.M. van Wyngaardt, Michael L. Smith, Angus H.H. Bowan, Christine M.B. Keevers, Emily L. Clark, Melek Zarifi, Anuradha Ravindra, D B Kulkarni, Ritu Sharma, M. Capogni, P. De Felice, Mauro Capone, P. Carconi, A. Fazio, Christophe Bobin, Paulo A Lima da Cruz, Carlos J. da Silva, Ronaldo Lins da Silva, Anderson Leiras, Johnny de Almeida Rangel, Monica Aguiar Leobino da Silva, Akira Iwahara, Denis E. Bergeron, Jeffrey T. Cessna, Ryan Fitzgerald, Lizbeth Laureano-Pérez, L. Pibida, Milton W Van Rooy, Joline Lubbe, Martin J van Staden, R. C. Shearman, J D Keightley, Andy Pearce, Natasha Ramirez, Emma Bendall, Sean P. Collins, Tomasz Ziemek, Edyta Lech, Paweł Saganowski, Marek Czudek, A. Listkowska, O. Nähle, Karsten Kossert, M. P. Takács, Matej Krivošík, Ivana Bonková,

Tópico(s)

Radioactivity and Radon Measurements

Resumo

Main text Since 1976, 30 laboratories have submitted 85 samples of 60 Co to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM), with comparison identifier BIPM.RI(II)- K1.Co-60. Recently, the PTB (Germany), the NIST (United States), the SMU (Slovakia), the BARC (India), the LNE-LNHB (France), the POLATOM (Poland), the ENEA-INMRI (Italy), the NPL (United Kingdom), the LNMRI-IRD (Brazil), the NMISA (South Africa) and the ANSTO (Australia) participated in the comparison and the key comparison reference value (KCRV) has been updated. The degrees of equivalence between each equivalent activity measured in the SIR and the updated KCRV have been calculated and the results are given in the form of a table. A graphical representation is also given. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Referência(s)
Altmetric
PlumX