Artigo Acesso aberto Revisado por pares

Ultra-high-resolution photon-counting detector CT in evaluating coronary stent patency: a comparison to invasive coronary angiography

2024; Springer Science+Business Media; Volume: 34; Issue: 7 Linguagem: Inglês

10.1007/s00330-023-10516-3

ISSN

1432-1084

Autores

Muhammad Taha Hagar, Martin Soschynski, Ruben Saffar, Moisés Felipe Molina-Fuentes, Jakob Weiß, Alexander Rau, Christopher Schuppert, Philipp Ruile, Sebastian Faby, David Schibilsky, C Von Zur Muehlen, Christopher L. Schlett, Fabian Bamberg, Tobias Krauß,

Tópico(s)

Cardiac Imaging and Diagnostics

Resumo

Abstract Objectives To determine the diagnostic accuracy of ultra-high-resolution photon-counting detector CT angiography (UHR PCD-CTA) for evaluating coronary stent patency compared to invasive coronary angiography (ICA). Methods Consecutive, clinically referred patients with prior coronary stent implantation were prospectively enrolled between August 2022 and March 2023 and underwent UHR PCD-CTA (collimation, 120 × 0.2 mm). Two radiologists independently analyzed image quality of the in-stent lumen using a 5-point Likert scale, ranging from 1 (“excellent”) to 5 (“non-diagnostic”), and assessed all coronary stents for the presence of in-stent stenosis (≥ 50% lumen narrowing). The diagnostic accuracy of UHR PCD-CTA was determined, with ICA serving as the standard of reference. Results A total of 44 coronary stents in 18 participants (mean age, 83 years ± 6 [standard deviation]; 12 women) were included in the analysis. In 3/44 stents, both readers described image quality as non-diagnostic, whereas reader 2 noted a fourth stent to have non-diagnostic image quality. In comparison to ICA, UHR PCD-CTA demonstrated a sensitivity, specificity, and accuracy of 100% (95% CI [confidence interval] 47.8, 100), 92.3% (95% CI 79.1, 98.4), and 93.2% (95% CI 81.3, 98.6) for reader 1 and 100% (95% CI 47.8, 100), 87.2% (95% CI 72.6, 95.7), and 88.6% (95% CI 75.4, 96.2) for reader 2, respectively. Both readers observed a 100% negative predictive value (36/36 stents and 34/34 stents). Stent patency inter-reader agreement was 90.1%, corresponding to a substantial Cohen’s kappa value of 0.72. Conclusions UHR PCD-CTA enables non-invasive assessment of coronary stent patency with high image quality and diagnostic accuracy. Clinical relevance statement Ultra-high-resolution photon-counting detector CT angiography represents a reliable and non-invasive method for assessing coronary stent patency. Its high negative predictive value makes it a promising alternative over invasive coronary angiography for the rule-out of in-stent stenosis. Key Points • CT-based evaluation of coronary stent patency is limited by stent-induced artifacts and spatial resolution. • Ultra-high-resolution photon-counting detector CT accurately evaluates coronary stent patency compared to invasive coronary angiography. • Photon-counting detector CT represents a promising method for the non-invasive rule-out of in-stent stenosis.

Referência(s)