Artigo Acesso aberto Revisado por pares

Delineation of Potential Groundwater Zones and Assessment of Their Vulnerability to Pollution from Cemeteries Using GIS and AHP Approaches Based on the DRASTIC Index and Specific DRASTIC

2024; Multidisciplinary Digital Publishing Institute; Volume: 16; Issue: 4 Linguagem: Inglês

10.3390/w16040585

ISSN

2073-4441

Autores

Vanessa Gonçalves, António Albuquerque, Pedro G. Almeida, L. M. Ferreira Gomes, Victor Cavaleiro,

Tópico(s)

Groundwater and Isotope Geochemistry

Resumo

The risk of aquifer contamination is determined by the interaction between the pollutant load and the vulnerability of an aquifer. Owing to the decomposition of bodies and degradation of artefacts, cemeteries may have a negative impact on groundwater quality and suitability for use due to the leaching of organic compounds (e.g., biodegradable organics, pharmaceuticals, and formaldehyde), inorganic compounds (e.g., nitrate and heavy metals), pathogenic bacteria, and viruses. Factors such as burial and soil type, rainfall amount, and groundwater depth may increase aquifer vulnerability to pollutants generated in cemeteries. The potential for groundwater contamination was investigated in two cemeteries of the Soure region in Portugal (Samuel–UC9 and Vinha da Rainha–UC10), using the classic DRASTIC model, followed by some adjustments, depending on the particularities of the locations, resulting in a Final Classification considered as Specific DRASTIC. By combining Remote Sensing (RS), Geographic Information System (GIS), and Analytical Hierarchy Process (AHP), groundwater potential zones (GWPZs) were identified, and aquifer vulnerability was assessed, which included the elaboration of thematic maps using GIS operation tools. The maps allowed for the identification of areas with different susceptibilities to contamination: from “Low” to “Very high” for the DRASTIC index and from “Very Low” to “Very high” for the Specific DRASTIC index. Although the difference between the UC9 and UC10 cemeteries is negligible, UC10 is more vulnerable because of its proximity to the community and critically important mineral water resources (such as Bicanho Medical Spa). The Specific model seems better-suited for describing vulnerability to cemeteries. Although there is limited groundwater quality data for the area, the development of vulnerability maps can identify areas that can be sensitive spots for groundwater contamination and establish procedures for pollution prevention.

Referência(s)
Altmetric
PlumX